Cisco 7604 + RSP720 3CXL + WS-X6704-10GEはポートのエラーカウンターを増やしますが、ポートを介した損失はありません


10

Cisco 7604 + RSP720 3CXL + WS-X6704-10GEはポートのエラーカウンターを増やしますが、ポートによる損失はありません。

   #sh interfaces Te3/4
  TenGigabitEthernet3/4 is up, line protocol is up (connected)
  Hardware is C7600 10Gb 802.3, address is 588d.09b4.8d80 (bia 588d.09b4.8d80)
  MTU 1500 bytes, BW 10000000 Kbit/sec, DLY 10 usec,
     reliability 255/255, txload 42/255, rxload 42/255
  Encapsulation 802.1Q Virtual LAN, Vlan ID  1., loopback not set
  Keepalive set (10 sec)
  Full-duplex, 10Gb/s
  Transport mode LAN (10GBASE-R, 10.3125Gb/s)
  input flow-control is off, output flow-control is off
  Clock mode is auto
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of "show interface" counters 3d03h
  Input queue: 0/75/291/291 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 1667291000 bits/sec, 244099 packets/sec
  5 minute output rate 1665910000 bits/sec, 243961 packets/sec
  L2 Switched: ucast: 4875 pkt, 1667250 bytes - mcast: 0 pkt, 0 bytes
  L3 in Switched: ucast: 0 pkt, 0 bytes - mcast: 0 pkt, 0 bytes mcast
  L3 out Switched: ucast: 0 pkt, 0 bytes mcast: 0 pkt, 0 bytes
     46982598919 packets input, 40800999530943 bytes, 0 no buffer
     Received 1748682 broadcasts (0 IP multicasts)
     0 runts, 0 giants, 0 throttles
     155706 input errors, 65000 CRC, 11401 frame, 0 overrun, 0 ignored
     0 watchdog, 0 multicast, 0 pause input
     0 input packets with dribble condition detected
     46985469520 packets output, 40792363160570 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 unknown protocol drops
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier, 0 pause output
     0 output buffer failures, 0 output buffers swapped out

ルータは、ポリシングを使用して、顧客の終端と顧客へのチャネル制限に使用されます。

更新:

#sh int te3/4 transceiver detail
ITU Channel not available (Wavelength not available),
Transceiver is internally calibrated.
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.

                              High Alarm  High Warn  Low Warn   Low Alarm
           Temperature        Threshold   Threshold  Threshold  Threshold
Port       (Celsius)          (Celsius)   (Celsius)  (Celsius)  (Celsius)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4        28.2                   70.0       60.0        5.0        0.0

                              High Alarm  High Warn  Low Warn   Low Alarm
           Voltage            Threshold   Threshold  Threshold  Threshold
Port       (Volts)            (Volts)     (Volts)    (Volts)    (Volts)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4        0.00                    N/A        N/A        N/A        N/A

                              High Alarm  High Warn  Low Warn   Low Alarm
           Current            Threshold   Threshold  Threshold  Threshold
Port       (milliamperes)     (mA)        (mA)       (mA)       (mA)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4         N/A                    N/A        N/A        N/A        N/A

           Optical            High Alarm  High Warn  Low Warn   Low Alarm
           Transmit Power     Threshold   Threshold  Threshold  Threshold
Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4         N/A         ++         0.9        0.4       -8.2       -8.1

           Optical            High Alarm  High Warn  Low Warn   Low Alarm
           Receive Power      Threshold   Threshold  Threshold  Threshold
Port       (dBm)              (dBm)       (dBm)      (dBm)      (dBm)
---------  -----------------  ----------  ---------  ---------  ---------
Te3/4         N/A         ++         0.9        0.4      -14.4      -15.0

「XENPACK to SFP +」および「Direct Attach Cable SFP + to SFP +」というアダプターを使用しています。これは診断を複雑にします。

成長カウンターの原因はどこにありますか?


1
ファイバーの信号強度をチェックし、ファイバーの終端をきれいにし(パッチパネルを含む)、光学部品を交換します。
マイクペニントン2013

直接接続ケーブル「SFP + to SFP +」とアダプター「XFP to SFP +」を使用しています。たぶん束の何かを交換する必要があります。
Allan Sundry 2013

すみません、「XENPACK to SFP +」と「Direct Attach Cable SFP + to SFP +」を使用しています
Allan Sundry 2013

@AllanSundry言い訳!
jwbensley 2013

回答:


4

CRCとフレーミングエラー、および一般的な入力エラーが表示されます。ポートのセットアップ中にこれが発生した場合、まだファイバーをいじっている人が原因である可能性があります。

通常の動作中にこれが発生する場合は、ほとんどの場合、光量が少ないか、ファイバまたは光学系に何らかのエラーがあることを示しています。

あなたは光のレベルを確認することができます

show interfaces transceiver 

これにより、サードパーティの光学部品の読み取り値が正しくない場合があることに注意してください。次に、光学素子のパワーバジェット/制限を調べて、仕様の範囲内にあるかどうかを確認する必要があります。

マイクが提案したように、すべてのファイバー終端をクリーニングしてみてください。それでも問題が解決しない場合は、光学素子を交換してみてください。

現時点では、エラーは小さすぎて気付かないほどですが、それはすぐに変わる可能性があります。回線の損失が突然多いため、午前3時に起こされるよりも、今すぐ修正することをお勧めします。

また、インターフェイス(エラー)カウンターの場合、Ciscoアウトプットインタープリターを使用して、表示されている内容を分析すると効果が出ることがあります。

https://www.cisco.com/pcgi-bin/Support/OutputInterpreter/home.pl

細かい分析をしてください。要点が欠けていることもありますが、何が問題なのかをすばやく把握するのに役立ちます。

更新

XENPAK / SFP +アダプターとDACケーブルを使用する場合、問題はどちらかが原因である可能性があります。アダプタやケーブルを交換してみてください。DACには光学部品がないため(銅線であるため)、interface transceiverコマンドを実行しても何も表示されません。

また、ケーブル長と電磁干渉の可能性があるため、DACで問題が発生する可能性があります。すべてが失敗した場合は、光学系と光ケーブルに切り替えて、それが役立つかどうかを確認してください。


「アウトプットインタープリタは、シスコのサービス契約を結んでいるCisco.comの登録ユーザーのみが利用できます。」記事をpdf形式で教えてもらえますか?
Allan Sundry 2013

アバス、.plセバスチャンがリンクしたCGIにはPDFコピーがありません。これは、showコマンドの出力を貼り付けて、潜在的な対策の推奨事項を取得できるツールです。
マイクペニントン2013

残念ながら、私はこのページにアクセスできません。アダプター「XENPACK to SFP +」および「Direct Attach Cable SFP + to SFP +」を使用すると、コマンド「sh int te3 / 4トランシーバー詳細」(最初の投稿に追加)の結果が空になります。
Allan Sundry 2013

さて、私は私の答えを更新しました。
Sebastian Wiesinger 2013

DACを光リンクに置き換えた後、エラーカウンターは増加を停止しました-8時間で約2つの入力エラー。
Allan Sundry 2013

9

損失は​​ありますが、影響は見られません。ディスプレイには、過去3日間と4時間の46982598919パケットのうち、155706の入力エラーのみが表示されています。これは.0003%のパケット損失です。そのため、テスト中に直接確認することは非常に困難です。

運用上の影響がない場合は、これは無視しても問題ありません。このような低レベルのパケット損失は、標準のIPネットワークではほとんど無視でき、上位層のプロトコルはそれに応じて適応します。

ソースを追跡することに専念している場合、それは困難になります。Mikeが指摘したように、最初のステップは信号強度を確認し(インターフェイスxxxxトランシーバーを表示します。これにはDOM機能を備えたモジュールが必要です)、パッチコードの終端点をクリーニングしてみます。それが機能しない場合は、パッチコードを交換してみてください。最後のストローとして、実際の光学モジュールを交換してください。